1kVA Sako Hybrid Invertor

$180.00

1. MPPT solar charge controller built inside.
2.Pure sine wave solar inverter.
3.Output Power factor l
4.Cost effective, stable quality
5.Auto restart while AC is recovering
6.Overload and short circuit protection
7.Configurable AC/Solar input priority via LCD setting
8.Compatible with mains voltage or generator power
9.Smart battery charge design for optimized battery performance
10.Selectable AC input voltage range for home appliances and personal computers

Category: Tag: Brand:

1. MPPT solar charge controller built inside.
2.Pure sine wave solar inverter.
3.Output Power factor l
4.Cost effective, stable quality
5.Auto restart while AC is recovering
6.Overload and short circuit protection
7.Configurable AC/Solar input priority via LCD setting
8.Compatible with mains voltage or generator power
9.Smart battery charge design for optimized battery performance
10.Selectable AC input voltage range for home appliances and personal computers

 

Mode No.
ISUN 1KW
ISUN 2KW
ISUN 3KW
Line Mode Specifications
Input Voltage Waveform
Sinusoidal (utility or generator)
Nominal Input Voltage
230Vac
AC input Range
170Vac-280V (Computer) ; 90Vac-280Vac(Home Appliances)
Nominal Input Frequency
50Hz / 60Hz (Auto detection)
Efficiency (Line Mode)
>95% ( Rated R load, battery full charged )
Transfer Time
10ms typical (UPS); 20ms typical (Appliances)
Inverter Mode Specifications
Rated Output Power
1KW
2KW
3KW
Output Voltage Waveform
Pure Sine Wave
Output Voltage Regulation
230Vac±5%
Output Frequency
50Hz/60Hz
Peak Efficiency
93%
Overload Protection
5s@≥150% load; 10s@105%~150% load
Surge Capacity
2* rated power for 5 seconds
Nominal DC Input Voltage
12.0Vdc
24.0Vdc
24.0Vdc
Cold Start Voltage
11.5Vdc
23.0Vdc
23.0Vdc
Low DC Warning Voltage
load < 50%
11.5Vdc
23.0Vdc
23.0Vdc
load ≧ 50%
11.0Vdc
22.0Vdc
22.0Vdc
Low DC Warning Return Voltage
load < 50%
11.8VDC
23.5Vdc
23.5Vdc
load ≧ 50%
11.5Vdc
23.0Vdc
23.0Vdc
Low DC Cut-off Voltage
load < 50%
10.7Vdc
21.5Vdc
21.5Vdc
load ≧ 50%
10.5Vdc
21.0Vdc
21.0Vdc
High DC Recovery Voltage
16.0Vdc
32Vdc
32Vdc
High DC Cut-off Voltage
16.5Vdc
33Vdc
33Vdc
No Load Power Consumption
<15W
<25W
<25W
Charge Mode Specifications
Utility Charging Mode
Charging Algorithm
3 steps
AC Charging Current (Max)
25Amp (INPUT=230Vac)
Voltage
14.1Vdc
28.2Vdc
28.2Vdc
Floating Charging Voltage
13.5Vdc
27Vdc
27Vdc
MPPT Solar Charging Mode
Charging Current
40Amp
System DC Voltage
12Vdc
24Vdc
24Vdc
Operating Voltage Range
18-80VDC
36-80Vdc
36-80Vdc
Max. PV Array Open Circuit Voltage
100Vdc
DC Voltage Accuracy
±0.3%
Max Charging Current {AC+ solar)
65Amp
BEST PANEL CONFIGUTATION
Max. generated from solar charger
40Amp, 500W
40Amp, 1000W
40Amp, 1000W
Best Panel configuration
250Wp*2PCS*30V
270Wp*2PCS*30V 2 Parallel
270Wp*2PCS*30V 2 Parallel
General Specifications
Safety Certification
CE
Operating Temperature Range
0℃-50℃
Storage temperature
-15℃-60℃
Humidity
5% to 95% Relative Humidity (Non-condensing)
Product Dimension (D*W*H), mm
343mm*250mm*122mm
343mm*250mm*122mm
473mm*297mm*107mm
Packing Size (mm)
400mm*320mm*190mm
400mm*320mm*190mm
534mm*390mm*193mm
Net Weight, kg
5.35KG
6.1KG
7.84
G.W. kg
5.85KG
6.6KG
9.24